Electrochemical Nitrogen Dioxide Sensor NO2-MD-600

Design Features

  • Quick Response
  • Excellent Selectivity
  • Linearity
  • Stability
  • High Reliability
  • Perfect Leak-proof Structure

Specifications [Sensitivity Characteristics]

Detection Gas Nitrogen Dioxide
Detection Range 0 ~ 30 ppm
Maximum Overload 150 ppm
Output Signal 600± 150 nA/ppm
Repeatability ± 2 %
Resolution 0.1 ppm
Typical Baseline Range (pure air) ±0.2 ppm
Typical Response Time (t90) < 25 seconds
Baseline Shift (- 20 ~ 40℃ ) < 0.2 ppm
Long Term Output Drift < 2 % / month
Expected Life Time > 3 years

Performance data conditions: 20℃, 50%RH and 1013mBar.

Operating Conditions

Operating Temperature -20~50℃
Operating Humidity 15~90%RH
Operating Pressure Range Atmospheric± 10 %
Recommended Load Resistor 33Ω
Bias Voltage Not required
Position Sensitivity None
Recommended Storage Temp. 0~20℃
Storage Life 6 months

Appearance and Dimensions