Electrochemical Ethylene Sensor C2H4-MD-100
Design Features
- High Sensitivity
- Excellent Selectivity
- Stability
- High Reliability
- Perfect Leak-proof Structure
Specifications [Sensitivity Characteristics]
Detection Gas | Ethylene |
---|---|
Detection Range | 0 ~ 100 ppm |
Maximum Overload | 200 ppm |
Output Signal | 100± 30 nA/ppm |
Repeatability | ± 2 % |
Resolution | 1ppm |
Typical Baseline Range (pure air) | -2 ppm to +5 ppm |
Typical Response Time (t60) | < 30 sec |
Baseline Shift (- 20 ~ 40℃ ) | < 5 ppm(typical) |
Long Term Output Drift | < 3 % / month |
Expected Life Time | 2 years |
Performance data conditions: 20℃, 50%RH and 1013mBar.
Operating Conditions
Operating Temperature | -20~50℃ |
---|---|
Operating Humidity | 15~90%RH |
Operating Pressure Range | Atmospheric± 10 % |
Recommended Load Resistor | 10Ω |
Bias Voltage | Not required |
Position Sensitivity | None |
Recommended Storage Temp. | 0~20℃ |
Storage Life | 6 months |