Electrochemical Hydrogen Sensor H2-MD-05
Design Features
- Linearity
- Quick Response
- Excellent Selectivity
- Stability
- High Reliability
- Perfect Leak-proof Structure
Specifications [Sensitivity Characteristics]
Detection Gas | Hydrogen |
---|---|
Detection Range | 0~40000 ppm |
Maximum Overload | 40000 ppm |
Output Signal | 5±3 nA/ppm |
Repeatability | < ±2% |
Resolution | 10 ppm |
Typical Baseline Range (pure air) | < ±50 ppm |
Typical Response Time (t90, 20℃) | 30 seconds |
Typical Baseline Shift (-40~40℃) | < ±50 ppm |
Long Term Output Drift | < 2%/month |
Expected Life Time | > 2 years |
Performance data conditions: 20℃ , 50%RH and 1013mBar, using MGK SENSOR recommended circuitry.
Operating Conditions
Operating Temperature | -40~50℃ |
---|---|
Operating Humidity | 15~90% RH |
Operating Pressure Range | 1atm ±10% |
Recommended Load Resistor | 10Ω |
Bias Voltage | Not required |
Position Sensitivity | None |
Recommended Storage Temp. | 0~20℃ |
Storage Life | Less than 6 months |
Physical Characteristics
Cap Color | Light blue |
---|---|
Weight | 4.5g (approx.) |